No.436 Precautions for the use of I/O product 21-06-2013


The output port(s) of I/O products is interfaced to relay(s).

The allowed output ports electrical currenct of voltage conditions are as follow.

Votage Condition : DC28V
Allowed current : 5A

The important thing is if current is over the allowed current, the relay may be damaged.
Please be careful when using I/O products' power on or off. (8~10fold increase)