No. 689 Re: Re: Re: Re: Re: Re: Re: Re: pulse mode in HTML 2012-06-27

Hello again.

To send the data(Modbus/TCP), you should develop the software to control the CIE-H12.

We provide sample sources of Modbus/TCP protocol at homepage.

And also you can use the Modmap as you know.

If you want test with ezManager, [Simple test] program is possible.

Please see the attachment.

You are able to test like that.

Thank you.

(Pulse fucntion of HTML is not supported yet. sorry)

> geve wrote:
> ------------------------------------
> Thanks for your reply.
> It is verry helpfull that I now know the ports used by ModBus. I will test it end of the week.
>
> You example for a 1 second pulse matches my code. What I don not know yet is where to put the code to conduct the CIE H12 by internet (is not a code to put in HTML or in EZmanager). How can I send the code to the CIE H12 or whitch program can I use to send the code ?
>
> Thanks for your help and time
>
> Regards, Gerrit
>
> > Sollae Systems wrote:
> > ------------------------------------
> > Hello.
> >
> > This is a technical support team of Sollae Systems.
> >
> > First of all, port will be forwared to use the Internet.
> >
> > If you didn't change the defalt port numbers,
> > please confirm it below to forward.
> >
> > 1. TCP 502 (for Modbus/TCP)
> > 2. UDP 50005 (for searching)
> > 3. TCP 80 (for HTTP)
> >
> > And p.26 of a document for Modbus/TCP protocol shows about Pulse function.
> >
> > Here is a example of pulse (1 second).
> >
> > [0x00 0x00 0x00 0x00 0x00 0x07 0x01 0x69 0x00 0x08 0x03 0xe8 0xff]
> >
> > 0x03 0xe8 means 1 second.
> >
> > Thank you.
> >
> > Have a nice day.
> >
> >
> >
> >
> > > geve wrote:
> > > ------------------------------------
> > > Good afternoon,
> > >
> > > In Modmap I can only see a CIE H12 in the same LAN. When entering the IP & port number from the CIE H12 in internet (by internet browser I can see and switch the output)the CIE H12 can not be found. In the routers (my LAN and the client LAN the CIE H12 port is forwarded (checked with a browser and a port check)
> > > Is there a extra port that needs to be forwarded to use Modmap ?
> > >
> > > I have read the Modbus TCP document but someware miss the way to send this code to the CIE H12. (do I need to make a magic package to send to the CIE H12 in the internet like I use to wake PC's on LAN, and where can I find information to make and send this package ?) If this is not the right way, where can I find the information to use Modbus/TCP to send a pulse to the CIE H12 ?
> > >
> > > Stan, are you willing to share your JAVA code ?
> > >
> > > Thank you for your attention and tips, regards, Gerrit

Attachment 20120627_h55_pulse.png
Writer Sollae Systems Company