No. 1165 Re: Virtual serial port problem 2013-02-20

Hello.

This is a technical support team of Sollae systems.

After open the virtual serial port in your program, you can check [Virtual Port Setup] field in ezVSP.

for example, (9600:NONE:8:1:NONE)

That means your control program uses that parameters.

ezVSP can't set serial parameters before I mentioned.

So you have to set it which is correct to CSE-H55N or your program.

If you are not sure your parameters, please test [Telnet Com Port control option].

To be use, Option will be checked both ezVSP and ezManager.

If you give us screenshots to eztcp@eztcp.com. it will be helpful.

Thank you.



> Michele wrote:
> ------------------------------------
> Hi,
> after a week of various test, no solution for my problem...
>
> recap: I've a CSE-H55N (properly configured) for the control of some serial devices. The control program is an old dos executable that when opens the serial connection only sets the speed of the port. In ezVSP I see that transmission occurs with parity even, when I need parity none.
>
> I tried other software that would allow me some kind of tunneling or pass through without success... any suggestions?

Writer Sollae Systems Company