한국어 English Chinese Russian
bannerbar

Q&A



Your information is protected by SSL.
No. 1205 Re: Problems EZL-50L with Netgear RP614 DHCP server 2013-07-10

Hi.

This is technical support team of Sollae Systems.

I am sorry but additional checking operations of the STS (status) and LINK LED is required.

If the LINK LED is on, assigning IP address might be failed.
In this case, the STS LED will flash 4 times at once.

If the 50L’s LINK LED is off and the module works fine with other network devices, please check the settings of Router’s port.
EZL-50L supports 10Mbit (Half Duplex) Ethernet so check if the port is set with another link speed or mode.

If the 50L’s LINK LED is off and the module does not work with any other devices, it might need repair.

I am sorry for your inconveniences.


===========================================================

> Daniel Tits wrote:
> ------------------------------------
> Hi,
>
> Bought some EZL-50L boards recently to incorporate in our products (satellite earth stations). Everything works fine with PC and cross-over cable, ezConfig etc.
>
> Now I want to connect to a local network (straight cable) with Netgear RP614 Router/Gateway using DHCP. Whatever I try no way to obtain connection. Of course I have activated DHCP on EZL. But the unit does not connect, the Rx data LED remains flashing rapidly all the time.
>
> For info, all other devices, over 10, connect correctly to the RP614 with DHCP. Could you please tell me what I am doing wrong?
>
> Thank you very much in advance.
> Best regards
> Daniel

Writer Sollae Systems Company