No. 363 Re: How to diagnose the state of my EZL 80C ? 2007-01-31

If you want configure EZL-80c by ezSerialConfig , you have to REMOVE the CF card from the EZL-80c and power it on.

You can check the serial port by hypher terminal or other serial terminals.
If you power EZL-80c on after removing CF card from the EZL-80c, EZL-80c outputs some message that show it enters ezSerialConfig mode.
The serial port configuration is 115200bps, 8bit, no parity, 1 stop bit.